What steps are necessary in order to run Dante DSP with Dante set to “Redundant Mode”?

All Dante devices ship with Dante in the default “Switched mode”. This allows units to be daisy chained, eliminating the need for 3rd party networking hardware. When in “Switched mode” if the Dante hardware is setup physically in a Redundant network configuration, traffic from the Primary Dante port will flow out the Secondary Dante port, and the Dante traffic from the Secondary Dante port will flow out the Primary Dante port. This creates a data feedback loop on the Dante network that will crash the Dante cards in the SymNet units. SymNet units with only Dante connections, such as the xIn 12 and the xOut 12, may become unresponsive until they are power cycled and the redundant Dante network switch is turned off or the redundant ports are unplugged from the secondary Dante network.

As such, to set the system to run Dante in “Redundant mode”, first go online with the system with only the Primary Dante port connected to the network or network switch. Alternatively, if the Secondary Dante ports are already connected to a network switch, turn off the secondary Dante network switch/switches. If the Secondary network switch cannot be turned off, or both Primary and Secondary Dante use the same network or switch, then unplug all Secondary Dante ports.

Next, go to Composer>Dante Flow Manager and hit the “Configure Dante…” button and set the Secondary Dante jack to “Redundant Network”. Then push the file to the SymNet system.

Verify via a DSP’s front panel display that the Dante mode now reads “Redundant”. When it does indicate “Redundant” mode is active, plug in the secondary Dante ports or turn on the secondary Dante network switch/switches.

How can we help?